Sartorius CB Operations Instructions

Browse online or download Operations Instructions for Kitchen scales Sartorius CB. Sartorius CB Operating instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 59
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
98648-009-72
Operating Instructions
Sartorius
Counting Scales
CB Models
Electronic Precision Scales
Page view 0
1 2 3 4 5 6 ... 58 59

Summary of Contents

Page 1

98648-009-72Operating InstructionsSartorius Counting ScalesCB ModelsElectronic Precision Scales

Page 2

10Connecting Electronic Peripheral Devices § Make absolutely sure to unplug the scale from AC power before you connect or disconnect a peripheral devi

Page 3

11Operating the Scale WeighingFeatures– Zeroing the scaleDepending on the prevailing ambient conditions, the display may not show a zero readout event

Page 4

12ExampleDetermine a weightSettings: factory settingsStep Press key Display/Printout1. Turn on scale [ON/OFF]0.0 g2. If necessary, zero scale [ZERO] 0

Page 5

13Calibration/AdjustmentPurposeTechnically, calibration means deter-mining the difference between theweight readout and the true weight(mass) of a sam

Page 6

14ExampleCalibrate/adjust the scaleSettings: factory settingsStep Press key Display/Printout1. Turn on scale, if power is off [ON/OFF]0.0 g2. If neces

Page 7

15Counting PurposeWith the counting program, you candetermine the number of parts thathave approximately the same averagepiece weight.Features– The mi

Page 8

16Selector– Turn this selector to set the referencesample quantity.– Each time you change the selector setting, the new reference sample quantity will

Page 9

17Example 1: Count parts into a containerMenu settings: factory settingsStep Press key Display/Printout1. Turn on scale, if power is off. [ON/OFF]2.

Page 10

18Example 2:Counting parts into a full containerSettings: (changes in factory settings required for this example)Autotare when the [START] is key is p

Page 11

19Toggle between Units PurposeWith this application program, you can toggle thedisplay of a weight back and forth between twounits.Features– Mass unit

Page 13

20Menu Code Unit Conversion Factor Printout(1. 7. 1)(3. 1. 1) Grams (o) 1.00000000000 o(1. 7. 2)(3. 1. 2) Grams (g) 1.00000000000 g(1. 7. 3)(3. 1. 3)

Page 14

21ExampleToggle unit from grams [g] (1st unit) to pounds [lb] (2nd unit)Settings (changes in the factory settings required for this example):Menu: Cou

Page 15

22Weigh Averaging PurposeUse this application program to deter-mine weights of moving samples (suchas animals) or weights under unstableambient condit

Page 16

23ExampleDetermine the weight of a sample under extremely unstable ambient conditions by calculating the average of 20 subweighing operations.Settings

Page 17

24Settings Setting the Parameters (Menu)This means you configure, or adapt, the scale to your user requirements by selecting theparameter settings fro

Page 18

25Parameter Settings (Overview)o Factory setting√ User settingMenu 1. Weighing 1.1. Adapt filter 1.1.1 Minimum vibration1.1.2 o Normal vibration1.1.3

Page 19

26Menu 1. Weighing 1.1. through 1.7. See previous page1.8. Display resolution 1 1.8.1 o Standard1.8.2 10+ higherresolution1.8.3 2+ higher resolution(S

Page 20

27Menu 1. through 2. See previous page3. Application 3.5. Storage parameter 3.5.1 o With stabilityparameters 3.5.2 With higher stability3.6. Reference

Page 21

28Menu 1. through 7. See previous page7. Printing 7.1. Line format 7.1.1 Without data ID codesof printout 7.1.2 With data ID codes7.1.3 With data ID

Page 22

29Generating a PrintoutPurposeYou can generate a printout of weightsas well as other measured values andidentification codes for documentationpurposes

Page 23

3Intended Use ContentsThe models of the CB Series are precision scales designed for the measurement of mass covering a range from 0.01 g and 64 kg.CB

Page 24

30Header Lines: ExamplesYou can configureABC HOBBY SHOP User-definedthe printout to includeLOS ANGELES User-defined2 user-defined header lines. The so

Page 25

31Data InterfacePurposeYour CB scale comes equipped with an interface port for connection to a computer or other peripheraldevice.You can use an on-li

Page 26

32Factory Settings of the ParametersTransmission rate: 1,200 baud (5. 1. 4)Parity: Odd (5. 2. 3)Stop bits: 1 stop bit (5. 3. 1)Handshake: Hardware han

Page 27

33Data Output Format with 16 CharactersDisplay segments that are not activated are output as spaces. Characters without a decimalpoint are output wit

Page 28

34Example: Output weight + 1255.7 gPosition 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16+** *125 5.7*g**CRLFPosition 1: Plus or minus sign or spacePosition

Page 29

35Special codes1234567891011121314151617181920 21 22Stat********––****** CR LFH*L**: Space H: Overload– –: Unstable weight L: Underload(stable weigh

Page 30

36Data Input FormatYou can connect a computer to your scale to send commands via the scale interface port to control the functions of the scale and ap

Page 31

37SynchronizationDuring data communication between the scale andan on-line device (computer), messages consisting of ASCII characters are transmitted

Page 32

38Software HandshakeThe software handshake is controlled via XON andXOFF. When a device is switched on, XON must be transmitted to enable any connect

Page 33

39Pin Assignment ChartFemale Interface Connector:25-position D-Submini, DB25S, with screw lock hardware for cable glandMale Connector Required (recomm

Page 34

4Warnings and Safety PrecautionsThe scale has been constructed inaccordance with the European Directivesas well as international regulations andstanda

Page 35

40Cabling Diagram– Diagram for interfacing a computer or different peripheral device to the scale using theRS-232C/V24 standard and cables up to 15 m

Page 36

41Error CodesError codes are shown on the main display for approx. 2 seconds, after which the programautomatically returns to the weighing mode.Displa

Page 37

42Display Cause Solutione 22 The weight is too light Increase the referenceor there is no sample sample quantityon the weighing pane 30 The interface

Page 38

43Care and MaintenanceServiceRegular servicing by a Sartorius technician will extend the service life of your scale andensure its continued weighing a

Page 39

44Safety Inspection If there is any indication that safe operation of thescale with the AC adapter is no longer warranted:§ Turn off the power and dis

Page 40

45Overview SpecificationsModel CB06 CB1 CB3 CB6CCX-N CCX-N CCX-N CCX-NWeighing capacity kg 0.6 1.2 3 6Readability g 0.1 0.2 0.5 1Counting resolution g

Page 41

46Model CB16 CB34 CB64EDX-N EDX-N EDX-NWeighing capacity kg 16 34 64Readability g 2 5 10Counting resolution g 0.2 0.5 1Tare range (subtractive) kg 16

Page 42

47Dimensions (Scale Drawings)Dimensions in millimetersModel a b c d e f g h iCB .. CCX-N 82 10 24 149 329 202 252 252 199CB .. EDX-N 121 12 24 238 429

Page 43

48Accessories (Options)Product Order No.Data printer YDP04Data printer YDP03-0CEfor generating printouts withdate/time, statistical evaluation and tra

Page 44

49SartoConnect data transfer software YSC01Lfor linking a Sartorius scale to a PCwith Windows 95/98 or NT operating software This software enables yo

Page 45

5General View of the Scale1234567891011121314151617181920211415222324

Page 46

50C MarkingThe equipment complies with the following EC Directives and European Standards:Council Directive 89/336/EEC "Electromagnetic compatibi

Page 47

Place emptycontaineron scaleStart countingSelect referencesample quantityPlace referencesample quantityon scaleSave referencesample quantityFill conta

Page 48

Leeren BehälteraufstellenZählen startenReferenz-stückzahleinstellenEingestellteStückzahlauflegenStückzahlübernehmenBehälterauffüllenReferenz-stückzahl

Page 49

Déposerrécipient videDémarrercomptageRégler nombrede piècesde référenceDéposer nombrede pièces régléMémoriser nombre de piècesRemplir récipientRégler

Page 50

Collocare ilcontenitore vuotoAvviareConteggioImpostare ilnumero di pezzidi riferimentoCollocare il numero di pezziimpostatoMemorizzareil numerodi pezz

Page 51

Placeraen tom behållarepå vågenStartaantalsräkningVäljreferensantalPlacerareferensantaletpå vågenLagrareferensantaletFyll behållarenVäljreferensantalP

Page 52

Tøm beholderpå vægtStart tællingVælg ref. antalAnbring ref.antal på vægtGem ref. antalFyld beholderVælg ref. antalAnbring ref.antal på vægtGem ref. an

Page 53

Plaats legecontainer opde balansStart tellenReferentie aantalingevenPlaatsreferentie aantalop de balansReferentie aantalopslaanVul de containerReferen

Page 54

èÓÒÚ‡‚ËÔ‡ÁÌËflÍÓÌÚÂÈÌÂ ̇‚ÂÁ̇ڇá‡ÔÓ˜ÌË·ÓÂÌÂÚÓàÁ·ÂËÂÙÂÂÌÚÌÓÍÓ΢ÂÒÚ‚ÓÔÓ·‡èÓÒÚ‡‚ËÂÙÂÂÌÚÌÓÚÓÍÓ΢ÂÒÚ‚ÓÔÓ·‡ ̇‚ÂÁ̇ڇá‡Ô˯ËÂÙÂÂÌÚÌÓÚÓÍÓ΢ÂÒÚ‚

Page 55

èÓÒÚ‡‚¸ÚÂÔÛÒÚÓÈ ÍÓÌÚÂÈ-Ì  ̇ ‚ÂÒ˚ëÚ‡ÚèÓ‰Ò˜fiڇᇉ‡ÈÚÂÒÔ‡‚. ÍÓÎ-‚Ó‰ÂÚ‡ÎÂÈèÓÎÓÊËÚÂÒÔ‡‚. ÍÓÎ-‚Ó‰ÂÚ‡ÎÂÈ Ì‡‚ÂÒ˚á‡ÔÓÏÌËÚ¸ÒÔ‡‚. ÍÓÎ-‚Ó‰ÂÚ‡ÎÂÈᇉ‡ÈÚÂÒÔ‡

Page 56

6Item (Spare Part Order No.)12 [ZERO] key: zeros the display. Setsthe display to zero. Zeroing is onlyallowed within the ± 2% range of the scale’s max

Page 58

7Getting StartedStorage and Shipping ConditionsDo not expose the scale to shock, vibra-tion, moisture or extreme temperature. Unpacking the Scale§ Aft

Page 59

8AC Power Connection/Safety PrecautionsUse only– Original Sartorius AC adapters; for Europe: 6971948§ Insert the right-angle plug into the jack on the

Page 60

9Installing the Batteries$ Batteries are not included with the equipment supplied.! Use only commercially available size C alkaline manganese batterie

Comments to this Manuals