Summary of Contents

Page 1 - , Practum

User ManualSecura®, Quintix®, Practum® Laboratory Balances98648-019-43

Page 2 - Contents

10Getting StartedUser Manual for Secura, Quintix, PractumInserting (or Removing) Glass Panels1) Holding it by its rear edge, pull the draft shield co

Page 3 - User Information

100SpecificationsUser Manual for Secura, Quintix, PractumModel-specific DataSecura®Model 224 124 613 513 313 213 6102 5102 3102 2102 1102 612Weighing

Page 4

101SpecificationsUser Manual for Secura, Quintix, PractumQuintix®Model 612 412 6101 5101 2101 6100 5100Weighing capacity g 610 410 6100 5100 2100 6100

Page 5 - Safety Information

102SpecificationsUser Manual for Secura, Quintix, PractumModel-specific DataVerified Models with Country-specific Type Approval CertificateSecura®Mode

Page 6 - Intended Use

103SpecificationsUser Manual for Secura, Quintix, PractumQuintix®Model 224-1x 1) 124-1x 1) 64-1x 1) 613-1x 1) 513-1x 1) 313-1x 1) 213-1x 1) 6102-1x 1)

Page 7 - General View of the Equipment

104SpecificationsUser Manual for Secura, Quintix, PractumPractum®Model 224-1x 1) 124-1x 1) 64-1x 1) 613-1x 1) 513-1x 1) 313-1x 1) 213-1x 1) 3102-1x 1)

Page 8

105Accessories (Options)User Manual for Secura, Quintix, PractumAccessories (Options)GeneralBattery set for standard laboratory balances YRB11ZDraft s

Page 9 - Installing the Balance

106Balance DimensionsUser Manual for Secura, Quintix, PractumBalance DimensionsSecura® models with readability of 0.1mgAll dimensions are given in mi

Page 10 - Getting Started

107Balance DimensionsUser Manual for Secura, Quintix, PractumQuintix® and Practum® models with readability of 0.1mgAll dimensions are given in millim

Page 11 - Choosing a Location

108Balance DimensionsUser Manual for Secura, Quintix, PractumModels with readability of 1 mgAll dimensions are given in millimeters

Page 12

109Balance DimensionsUser Manual for Secura, Quintix, PractumModels with readability of > 10 mgAll dimensions are given in millimeters

Page 13 - Warm-up Time

11Getting StartedUser Manual for Secura, Quintix, PractumChoosing a Locationt Select the right setup location:– Set up the device on a stable, even

Page 14 - Leveling

110 User Manual for Secura, Quintix, Practum:89ZXaVgVi^dcd[8dc[dgb^inFor verified balances, the conformity declaration supplied with the balance is

Page 15 - (Quintix

111User Manual for Secura, Quintix, Practum EC Type-approval Certificate

Page 16 - Below-balance Weighing

112 User Manual for Secura, Quintix, PractumPlates and Markings

Page 17 - Anti-theft Locking Device

113User Manual for Secura, Quintix, PractumPlates and Markings

Page 20 - Setting the Language

Sartorius Lab Instruments GmbH & Co. KG Weender Landstrasse 94–108 37075 Goettingen, Germanywww.sartorius.comCopyright by Sartorius, Goettingen,

Page 21 - Operating Concept

12Getting StartedUser Manual for Secura, Quintix, PractumPower Connection (Power Supply)AC Adaptor AssemblyUsing the wrong power plug adaptors may cau

Page 22 - The Menu

13Getting StartedUser Manual for Secura, Quintix, Practum Removing/Replacing the AC Adaptort Unlock (1) the AC adaptor and then detach (2) it.Power

Page 23

14Getting StartedUser Manual for Secura, Quintix, PractumLevelingThe balance must be level to ensure precise weighing results. Leveling the balance co

Page 24 - Mixing (Secura

15Getting StartedUser Manual for Secura, Quintix, Practum Leveling with a Conventional Level Indicator (Quintix® and Practum®)LRRLLR The Quintix® a

Page 25

16Getting StartedUser Manual for Secura, Quintix, PractumBelow-balance WeighingA port for a below-balance weighing hook is located on the bottom of th

Page 26 - MixingWeighing

17Getting StartedUser Manual for Secura, Quintix, PractumAnti-theft Locking Devicet A “Kensington” key lock cable can be installed at the fastening p

Page 27 - Français

18Moving the BalanceUser Manual for Secura, Quintix, PractumMoving the BalanceMoving the Balance over Short Distances in the LabAvoid glass breakage,

Page 28 - Weighing

19Using the BalanceUser Manual for Secura, Quintix, PractumUsing the BalanceSwitching the Balance On/Off (Standby) 0.00Max 2100 g d=0.01 g y The Lev

Page 29 - Weighing

2ContentsUser Manual for Secura, Quintix, PractumContentsContents ... 2User Information ...

Page 30 - A or D is selected

20Using the BalanceUser Manual for Secura, Quintix, PractumSetting the LanguageThe display text is given in English as a default. To change the langua

Page 31 - Automatic print

21Using the BalanceUser Manual for Secura, Quintix, PractumOperating ConceptThis section describes the operational possibilities of your balance. Ope

Page 32 - Identifier

22Using the BalanceUser Manual for Secura, Quintix, Practum The MenuAll balance application and settings can be accessed via the balance menu. t T

Page 33 - USB Port

23Using the BalanceUser Manual for Secura, Quintix, PractumEnter Figures on the Keypad gMin123456789+/- 0 .C+0000000 Numerical values can be entered

Page 34

24Using the BalanceUser Manual for Secura, Quintix, Practum Accessing an Application in the MenuThe right-hand side of the display shows available ap

Page 35 - Acoustic signal

25Using the BalanceUser Manual for Secura, Quintix, Practum Statistics (Secura® and Quintix® only; see page46)Use this application to save weight

Page 36 - Enable service mode

26System Settings (Setup Menu)User Manual for Secura, Quintix, PractumSystem Settings (Setup Menu)The Settings (Setup menu) contain all basic settings

Page 37 - Lock Menu (Quintix

27System Settings (Setup Menu)User Manual for Secura, Quintix, PractumList of Available SettingsThis section contains information on all basic balance

Page 38 - D to tare the balance

28System Settings (Setup Menu)User Manual for Secura, Quintix, Practum Device Information Device informationManufacturer: SartoriusModel: SECURA2102Se

Page 39 - Mass Unit Conversion

29System Settings (Setup Menu)User Manual for Secura, Quintix, PractumSafety LevelThe Secura® models monitor the following at all times:– whether the

Page 40

3User InformationUser Manual for Secura, Quintix, PractumUser InformationWarning/Danger SymbolsWarning/danger symbols used in these instructions: Th

Page 41 - Switching SQmin On/Off

30System Settings (Setup Menu)User Manual for Secura, Quintix, PractumAmbient conditions menu option:t Choose whether the conditions at the balance l

Page 42 - Max 2100 g d

31System Settings (Setup Menu)User Manual for Secura, Quintix, Practum Printout PrintoutPrintoutManual printAutomatic print Configure the settings fo

Page 43 - D to tare

32System Settings (Setup Menu)User Manual for Secura, Quintix, Practum Identifier (Secura® only) IdentifierSet device IDSet additional IDBatch ID func

Page 44 - Component

33System Settings (Setup Menu)User Manual for Secura, Quintix, Practum USB Port USB portDevice / ProtocolRS232 ConfigurationKeyboard emulationSpreadsh

Page 45 - Printing Results

34System Settings (Setup Menu)User Manual for Secura, Quintix, PractumAdditional menu option if “PC spreadsheet format” has been selected:In Spreadshe

Page 46 - Statistics

35System Settings (Setup Menu)User Manual for Secura, Quintix, Practum2) Connection with Sartorius lab printer via the supplied printer cableDevice /

Page 47

36System Settings (Setup Menu)User Manual for Secura, Quintix, Practum More Settings More settingsSet passwordReset settingsUSB mass storageEnable ser

Page 48

37System Settings (Setup Menu)User Manual for Secura, Quintix, PractumLock Menu (Quintix® and Practum®)Use this function to lock or unlock the menu.t

Page 49

38WeighingUser Manual for Secura, Quintix, PractumWeighing Purpose: Use this application to determine the weight of a sample within the device'

Page 50

39WeighingUser Manual for Secura, Quintix, PractumMass Unit Conversion Purpose: Configure the weight unit and accuracy of the weight value. Not all

Page 51 - Sum button

4User InformationUser Manual for Secura, Quintix, PractumThe following symbols are used in these instructions:t Indicates a required actiony Describ

Page 52 - Density of liquid

40WeighingUser Manual for Secura, Quintix, Practum Conversion Factors for Weight UnitsThe table contains common weight units and their conversion fac

Page 53

41WeighingUser Manual for Secura, Quintix, PractumSQmin Minimum Weighing (Secura® only) Purpose: This function is used to compare the weight value w

Page 54 - Weight in medium

42WeighingUser Manual for Secura, Quintix, PractumIndividual Identifiers (Secura® only) Purpose: You can define identifiers for the following print

Page 55 - O at Temperature T (in °C)

43Mixing (Secura® and Quintix® only)User Manual for Secura, Quintix, PractumMixing (Secura® and Quintix® only) Purpose: Use this application to weig

Page 56 - Reference

44Mixing (Secura® and Quintix® only)User Manual for Secura, Quintix, Practum t Place the first component on the weighing pan. Max 2100 g d=0.01 g1

Page 57

45Mixing (Secura® and Quintix® only)User Manual for Secura, Quintix, Practum Net1 t To view the total weight, select the Net1/Total button on the we

Page 58 - Net button again

46Statistics (Secura® and Quintix® only)User Manual for Secura, Quintix, PractumStatistics (Secura® and Quintix® only) Purpose: Save weight values a

Page 59 - Conversion

47Statistics (Secura® and Quintix® only)User Manual for Secura, Quintix, Practum t Select D to tare. t Place the first component on the weighin

Page 60 - 16.03335

48Statistics (Secura® and Quintix® only)User Manual for Secura, Quintix, Practum Number of components: n 5Average: x 13.49 gStandard deviation: s 3

Page 61 - Unstable condition

49Totalizing Components (Secura® and Quintix® only)User Manual for Secura, Quintix, PractumTotalizing Components (Secura® and Quintix® only) Purpos

Page 62 - Measurements

5Safety InformationUser Manual for Secura, Quintix, PractumSafety InformationGuidelines and General Information– The balance complies with EU Directi

Page 63 - Checkweighing

50Totalizing Components (Secura® and Quintix® only) User Manual for Secura, Quintix, Practum t Place the first component on the weighing pan.Max 2

Page 64

51Totalizing Components (Secura® and Quintix® only) User Manual for Secura, Quintix, Practumt Continue this procedure with additional components. Net

Page 65

52DensityUser Manual for Secura, Quintix, PractumDensity Purpose: The density of solids can be determined using the buoyancy method. The density is

Page 66

53DensityUser Manual for Secura, Quintix, Practum Density of liquidg/cm30.9982 t To change the density of the buoyancy liquid, select the gray butto

Page 67

54DensityUser Manual for Secura, Quintix, Practum t To save the weight value, select v. t Remove the sample from the weighing pan and place it

Page 68 - Counting

55DensityUser Manual for Secura, Quintix, Practum Density Values of H2O at Temperature T (in °C)T/°C 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.910. 0.99

Page 69 - Qnt button on the weighing

56PercentageUser Manual for Secura, Quintix, PractumPercentage Purpose: This application is used to determine the percentage share or the percentage

Page 70 - Calibration and Adjustment

57PercentageUser Manual for Secura, Quintix, Practum t Place the reference sample on the weighing pan.Max 2100 g d=0.01 gReference%10.014.32+ y

Page 71 - CAL-Intern

58PercentageUser Manual for Secura, Quintix, Practum % t To view the sample weight, select the % button on the weighing display.Max 2100 g d=0.01 g1

Page 72

59Conversion (Secura® and Quintix® only)User Manual for Secura, Quintix, PractumConversion (Secura® and Quintix® only) Purpose: Use this application

Page 73

6Safety InformationUser Manual for Secura, Quintix, PractumHazards during Installation and Operation If glass breaks, there is a risk of injury posed

Page 74 - ISO/GLP-compliant Printout

60Conversion (Secura® and Quintix® only)User Manual for Secura, Quintix, Practum t Place the sample on the weighing pan.Max 2100 g d=0.01 g81.4END

Page 75

61Unstable ConditionUser Manual for Secura, Quintix, PractumUnstable Condition Purpose: Use this application with moving samples (such as live anima

Page 76 - USB Port

62Unstable ConditionUser Manual for Secura, Quintix, Practum t Place the animal in the container. t If the start of measurement is set to Man

Page 77 - Device / Protocol

63CheckweighingUser Manual for Secura, Quintix, PractumCheckweighing Purpose: Use this application to check whether a weight value falls within the

Page 78 - Connections – Keyboards

64CheckweighingUser Manual for Secura, Quintix, Practum t Select D to tare. t Select w. t Place the sample on the weighing pan. Max 2100 g d

Page 79

65Peak HoldUser Manual for Secura, Quintix, PractumPeak Hold Purpose: Use this application to calculate the maximum weight value of a sample (peak v

Page 80 - Storage connect to PC?

66Peak HoldUser Manual for Secura, Quintix, Practum Max 2100 g d=0.01 g44.80ENDApplyHold+ y The maximum measured weight value is displayed and kept

Page 81

67CountingUser Manual for Secura, Quintix, PractumCounting Purpose: Use this application to determine the number of parts of approximately equal wei

Page 82

68CountingUser Manual for Secura, Quintix, Practum t Select D to tare. t Place the set number of reference samples on the weighing pan. Referen

Page 83 - Interface Specification

69CountingUser Manual for Secura, Quintix, Practum Qnt t To view the total weight of the sample, select the Qnt button on the weighing display.4.95+

Page 84

7General View of the EquipmentUser Manual for Secura, Quintix, PractumGeneral View of the EquipmentPos. Name and Function Pos. Name and Function1 Weig

Page 85

70Calibration and AdjustmentUser Manual for Secura, Quintix, PractumCalibration and Adjustment Background During calibration, a calibration weight is

Page 86 - Data Input

71Calibration and AdjustmentUser Manual for Secura, Quintix, PractumCalibration/Adjustment using an Internal Calibration Weight (Secura® and Quintix®

Page 87

72Calibration and AdjustmentUser Manual for Secura, Quintix, PractumCalibration/Adjustment using an External Calibration Weight An external calibrati

Page 88 - Status Messages

73Calibration and AdjustmentUser Manual for Secura, Quintix, PractumAutomatic Calibration/Adjustment with isoCALFully automatic calibration/adjustmen

Page 89 - “USB Devices” Error Message

74ISO/GLP-compliant PrintoutUser Manual for Secura, Quintix, PractumISO/GLP-compliant Printout CharacteristicsThe device information, ID, and the curr

Page 90 - Transporting the Balance

75ISO/GLP-compliant PrintoutUser Manual for Secura, Quintix, Practumy The ISO/GLP printout can have the following lines (configuration using date/ti

Page 91

76USB PortUser Manual for Secura, Quintix, PractumUSB PortCommunication with Peripheral Devices Purpose: The interface is used to exchange data with

Page 92

77USB PortUser Manual for Secura, Quintix, Practum Direct Transfer of Data (PC)Prerequisites:– PC with operating system Windows 7, Vista, XP, or 200

Page 93 - Care and Maintenance

78USB PortUser Manual for Secura, Quintix, Practumy With the “PC spreadsheet format” setting on the balance, Microsoft Excel 2010 has the following d

Page 94 - Cleaning the Draft Shield

79USB PortUser Manual for Secura, Quintix, Practum t Configure how Microsoft Excel treats numbers: In Excel, go to File – Options – Advanced – Edi

Page 95 - 4) Lift the frame cover

8Getting StartedUser Manual for Secura, Quintix, PractumGetting Started The balance must be disconnected from the mains power for all assembly work. U

Page 96

80USB PortUser Manual for Secura, Quintix, Practum – PC text format set on balance and Microsoft Word 2010 (example): Gross/Tare/Net(2) USB Con

Page 97 - Assembling the Draft Shield

81USB PortUser Manual for Secura, Quintix, Practum t To install the installation program for the USB driver on the PC: Click on the appropriate r

Page 98 - Disposal

82USB PortUser Manual for Secura, Quintix, Practum Connecting with Sartorius Lab Printer YDP30, YDP40Printer YDP30, YDP40OffMini-A Type-B2)Device (Sl

Page 99

83USB PortUser Manual for Secura, Quintix, PractumInterface SpecificationData OutputThe data output can be activated either manually when a print comm

Page 100 - Specifications

84USB PortUser Manual for Secura, Quintix, PractumSpecial OutputsPosition 1 2345678910111213141516******––******CRLFor ******Low*****CRLFor ******High

Page 101

85USB PortUser Manual for Secura, Quintix, Practum Data Output Format with 22 CharactersWhen data is output in this format, ID codes with six charact

Page 102

86USB PortUser Manual for Secura, Quintix, Practum Data InputInterface Commands (Commands)The computer connected via the data interface can send contr

Page 103

87USB PortUser Manual for Secura, Quintix, PractumOverview of Interface Commands (Commands)Format Command Action/Function Comments1 ESC P Print Corres

Page 104

88Status MessagesUser Manual for Secura, Quintix, PractumStatus MessagesMessages appear on the display when certain events occur:– Info messages are

Page 105 - Accessories (Options)

89Status MessagesUser Manual for Secura, Quintix, Practum Calibration/Adjustment Error Messages“The balance needs to perform eCheck!”when eCheck is re

Page 106 - Balance Dimensions

9Getting StartedUser Manual for Secura, Quintix, PractumInstalling the BalanceBalance with Draft Shieldt Install the following parts in the order lis

Page 107 - and Practum

90Transporting the BalanceUser Manual for Secura, Quintix, PractumTransporting the BalancePlease use the original packaging for shipping. Packaging ca

Page 108

91Transporting the BalanceUser Manual for Secura, Quintix, Practumt Turn the draft shield lock to “unlocked.”t Next, remove the draft shield from th

Page 109

92Transporting the BalanceUser Manual for Secura, Quintix, Practumt Put packing pads over the glass panels.t Insert the AC adaptor from the cardboar

Page 110 - :89ZXaVgVi^dcd[8dc[dgb^in

93Care and MaintenanceUser Manual for Secura, Quintix, PractumCare and MaintenanceServiceTo ensure the continued accuracy of your balance, we recommen

Page 111 - EC Type-approval Certificate

94Care and MaintenanceUser Manual for Secura, Quintix, PractumDo not clean the following parts with acetone or aggressive cleaning agents: control pan

Page 112 - Plates and Markings

95Care and MaintenanceUser Manual for Secura, Quintix, PractumC) Remove the front and rear glass: 4) Lift the frame cover. 5) Pull the frame cover

Page 113

96Care and MaintenanceUser Manual for Secura, Quintix, Practum7) Pull out the draft shield frame from the side of the guide and remove the draft shie

Page 114

97Care and MaintenanceUser Manual for Secura, Quintix, PractumAssembling the Draft Shieldt Place the front and rear glass panels back into the guide.

Page 115

98DisposalUser Manual for Secura, Quintix, PractumDisposalThe packaging consists of environmentally friendly materials that can serve as secondary raw

Page 116

99SpecificationsUser Manual for Secura, Quintix, PractumSpecificationsGeneral DataAC AdaptorSartorius AC adaptor module 6971790 with interchangeable